Free-Cooling Chiller

Magnetic-Bearing Free-Cooling Chiller
Manufacturer in China

GEAREA  chillers are designed for data center cooling, combining oil-free, variable-speed magnetic-bearing centrifugal compressors, EC fans, and integrated free-cooling coils. Variable-speed operation matches changing loads, while free cooling reduces mechanical cooling demand when outdoor conditions permit.

  • Free-Cooling Chiller
  • Free-Cooling Chiller
  • Free-Cooling Chiller
  • Free-Cooling Chiller

Free-Cooling Chiller

  • Oil-Free Magnetic-Bearing Technology

Oil-free, variable-speed magnetic-bearing centrifugal compressors reduce mechanical friction and adjust operation to changing loads, supporting efficient part-load performance.

  • Integrated Free Cooling

Free-cooling coils are integrated into the condenser module. When outdoor temperatures are suitable, ambient cooling reduces the demand on the mechanical refrigeration system.

  • Efficient Heat Transfer and Variable-Flow Operation

An efficient evaporator, finned-coil condenser, and EC fans work together to support efficient cooling. Variable-flow operation can reduce pumping energy at part load when coordinated with the system pumps.

  • Multiple Independent Refrigerant Circuits

Multiple independent refrigerant circuits help limit the impact of a single-circuit failure. Redundant capacity is configured and verified against project loads and cooling-continuity requirements.

Cooling Plant Equipment for Critical IT Environments

Chillers can be configured around changing data center loads, year-round operating requirements, and redundancy targets to support different project scales and development phases.

AI and HPC Data Centers

Cooling plant selection matched to the water-system requirements of high-density computing facilities.

Large Data Centers

Chiller configurations matched to project loads and cooling-continuity requirements.

Phased Developments

Capacity planning aligned with initial loads and future expansion.

Cooling Plant Retrofits

Efficiency and free-cooling opportunities assessed against the existing water system.

Selection and Configuration Support for GEAREA Magnetic-Bearing Chillers

Compressor combinations, heat exchangers, and fan configurations are selected to match project cooling loads, entering and leaving fluid temperatures, fluid properties, ambient conditions, efficiency targets, and redundancy requirements.

Flexible Electrical and Control Options

Options include dual power inputs, automatic transfer switches (ATS), power-factor correction capacitors, and ultracapacitors. The electrical arrangement should be confirmed against site power conditions and cooling-continuity requirements.

Water-System Integration

Selection considers water or glycol-based fluids, design flow, allowable pressure drop, and temperature requirements. Variable-flow operation should be coordinated with the system pumps and controls.

More About Free-Cooling Chiller

R1234zeFree-Cooling ChillerGMAC250GMAC400GMAC500GMAC650GMAC800GMAC950GMAC1200GMAC1400
Outdoor Air: 95°F
Fluid: 30% EG
EWT/LWT:
78.8°F / 68°F
Nominal cooling capacity (tons)94128171199242270370398
EER (Btu/Wh)15.915.815.715.615.316.215.015.0
Power Input (kW)101138177212261278424471
(ZET), °F4747505050515048
ComponentsNo. of Compressors22333344
No. of Refrigerant Circuits22333344
Power Supply460 V / 3 Ph / 60 Hz
Fans68121416202222
EvaporatorShell-and-Tube
CondenserFinned Coil
Free-CoolingFree-Cooling Coil
DimensionsLength (in.)136.2177.6260.2301.6342.9425.6466.9466.9
Width (in.)88.688.688.688.688.688.688.688.6
Height (in.)109.8109.8109.8109.8109.8109.8109.8109.8

Get a Fast Quote for Energy-Saving Cleanroom HVAC System

GEAREA designs and manufactures precision temperature and humidity control systems for factories and clean environments. We offer customized solutions that effectively reduce operating costs—typically saving up to 40% on electricity consumption. Please tell us your needs, and we will provide you with the best configuration and budget quote.