x
Send Your Inquiry Today
Quick Quote
Heat Recovery Air Handling Unit Manufacturer

Heat Recovery Air Handling Unit Manufacturer

GEAREA offers advanced heat recovery air handling units designed to enhance energy efficiency. Our systems are ideal for environments with centralized exhaust and heat recovery capabilities, cutting energy consumption by up to 40-50% while ensuring precise temperature and humidity control.

  • GRDR Heat Recovery Air Handling Unit1
  • GRDR Heat Recovery Air Handling Unit2
  • GRDR Heat Recovery Air Handling Unit3
  • GRDR Heat Recovery Air Handling Unit4
  • GRDR Heat Recovery Air Handling Unit5
  • GRDR Heat Recovery Air Handling Unit1
  • GRDR Heat Recovery Air Handling Unit2
  • GRDR Heat Recovery Air Handling Unit3
  • GRDR Heat Recovery Air Handling Unit4
  • GRDR Heat Recovery Air Handling Unit5
GRDR Series

Heat Recovery Air Handling Unit (Heat Recovery Type)

  • High flexibility: Featuring a modular design, GEAREA heat recovery air handling unit can be customized to fit your project requirements.
  • Comfortable temperature range: Adjustable air supply temperature of 15–25°C allows you to control your working environment, perfectly meeting various process requirements and comfort needs.
  • Controllable Humidity: An adjustable humidity range of 8 to 12 g/kg (dry air) enables precise humidity control, providing the strongest guarantee for your production.
  • Easy Operation: We have an intelligent control panel. Temperature and humidity can be set with a single click, reducing operational complexity, minimizing on-site errors, and allowing you to easily maintain a stable environment.

Why Choose Our Heat Recovery Air Handling Unit

GEAREA heat recovery air handling unit delivers ultra-quiet, precisely controlled, desert-dry air while significantly reducing energy consumption with its patented humidity-control and deep dehumidification technologies.

Noise Reduction
Noise Reduction

GEAREA’s distributed damping vibration and noise control technology enables the unit to operate as quietly as 65 dB(A).

Precise Environment Control
Precise Environment Control

GEAREA patented condensing heat redistribution system along with the built-in refrigeration cycle allows for precise humidity and temperature control.

Variable Humidity Options
Variable Humidity Options

GEAREA advanced humidity control technology can raise supply air humidity to 12 g/kg in summer and lower to 8 g/kg in winter.

Energy Efficiency
Energy Efficiency

DC inverter compressor and EC fans achieves saves  energy reduction compared with conventional systems.

GEAREA Engineering Strength in Heat Recovery Air Handling Unit

GEAREA heat recovery air handling units are ideal for facilities with centralised exhaust systems, capturing energy from exhaust air to reduce the load on your main heating and cooling systems. This helps you significantly cut energy consumption and operating costs while keeping temperature and humidity stable. At the same time, it lightens the load on existing equipment, extending service life and giving your building a more cost-effective, reliable HVAC solution.

GEAREA Engineering Strength in Heat Recovery Air Handling Unit

More About Our Heat Recovery Air Handling Unit

ModelGRDR-02GRDR-03GRDR-04GRDR-05GRDR-06GRDR-07GRDR-08GRDR-10GRDR-12GRDR-14GRDR-16GRDR-18GRDR-20
AirflowRatedm³/h2000300040005000600070008000100001200014000160001800020000
Cooling & Dehumidification OperationRated Cooling CapacitykW37.756.475.193.8112.5131.2149.9187.3224.7262.1299.5336.9374.3
Rated Dehumidification Capacitykg/h30.846.161.476.792107.3122.6153.2183.8214.4245.0275.6306.2
Full-Load Cooling CapacitykW43.464.986.4107.9129.4150.9172.4215.4258.4301.4344.4387.4430.4
Full-Load Dehumidification Capacitykg/h31.847.663.479.295.0110.8126.6158.2189.8221.4253.0284.6316.2
Heating & Humidification OperationRated Heating CapacitykW22.733.945.156.367.578.789.9112.3134.7157.1179.5201.9224.3
Rated Humidification Capacitykg/h15.423.030.638.245.853.461.076.291.4106.6121.8137.0152.2
Full-Load Heating CapacitykW40.861.081.2101.4121.6141.8162.0202.4242.8283.2323.6364.0404.4
Full-Load Humidification Capacitykg/h24.436.548.660.772.884.997.0121.2145.4169.6193.8218.0242.2
DimensionsLengthmm4800480049004900510051005100520052005500450047004700
Widthmm80090012001300145016501650200020002200220024002400
Heightmm1550165016501650175017501900200022002200150016501650
Power Supply380V/3N/50Hz
Installed PowerStandard StaticPressurekW6.9910.3113.0115.9117.8120.5123.9128.7134.5143.3147.1149.6153.21
NoiseStandard StaticPressuredB(A)59595961616363646465656666
Chilled WaterRated Flowratet/h3.14.66.27.79.210.812.315.418.421.524.531.935.5
Connection Pipe SizeDNDN32DN40DN50DN50DN50DN65DN65DN65DN80DN80DN80DN80DN100
Water-Side Pressure DropkPa38454739434446424645465148
Cooling Water (32/37℃)Rated Flowratet/h3.65.47.18.910712.514.217.821.324.928.431.935.5
Connection Pipe SizeDNDN32DN40DN50DN50DN50DN65DN65DN65DN80DN80DN80DN80DN100
Water-Side Pressure DropkPa12151313161517151918161720
Humidification SectionHot Water Flowratet/h1.52.33.03.74.55.26.07.48.910.411.913.414.8
Hot Water Piping Connection SizeDNDN25DN32DN32DN32DN40DN40DN50DN50DN50DN50DN65DN65DN65
Humidifier Make-Up Water Flowratet/h0.020.040.050.060.070.080.10.120.140.170.190.220.24
Humidifier Make-Up Water Piping Connection SizeDNDN25DN25DN25DN25DN25DN25DN25DN25DN25DN25DN25DN25DN25
Operating Weightkg76079010901220151017802030255028703220362044304860
CompressorTypeInverter Scroll Compressor
QuantityUnit1111111111111
ChillerR410A
Humidification Circulation PumpTypeMagnetic Drive Pump
QuantityUnit1111111111111
Wireless Data UplinkOptional
Communication ProtocolModbus RTU Protocol

Get a Fast Quote for Energy-Saving Cleanroom HVAC System

GEAREA designs and manufactures precision temperature and humidity control systems for factories and clean environments. We offer customized solutions that effectively reduce operating costs—typically saving up to 40% on electricity consumption. Please tell us your needs, and we will provide you with the best configuration and budget quote.