Low Temperature Inverter Heat Pump
- Applicable for low ambient: suitable for operation in climates with outdoor temperatures down to −15°C ambient, meeting winter heating needs in most regions.
- Reliable winter heating: pre-defrost technology keeps the heat exchanger base free of ice, ensuring stable heating performance in cold and humid conditions.
Why Choose GEAREA Low Temperature Heat Pump?
GEAREA low temperature inverter heat pump delivers powerful performance across four key aspects: smart control, high efficiency, reliable protection, and smooth, quiet operation.

Intuitive UI with smart control enables simple operation, real-time monitoring, and quick adjustment of key system parameters.

High-efficiency heat exchange and cooling are achieved through a plate heat exchanger with optimized refrigerant distribution.

Multiple preventive protections safeguard key components and the system, enhancing long-term reliability.

Quiet operation and inverter-based smooth output reduce noise and vibration, improving user comfort.
Effortless Comport by GEAREA Low Temperature Inverter Heat Pump
With GEAREA low-temperature inverter heat pumps, you can enjoy stable and precise temperature control year-round. Our DC inverter compressors adjust cooling capacity according to your building’s actual needs, ensuring lower energy costs and a stable indoor environment. Intelligent inverter control improves operating efficiency under partial load, reduces the load on critical components, and extends the system’s lifespan. This means you’ll have a quieter, more reliable system that not only maintains indoor comfort but also reduces your operating costs.

More About Low Temperature Inverter Heat Pump
- Data Sheet
| Model | GAVH 05- Y2P | GAVH 08- Y2P | GAVH 10- Y2P | GAVH 13- Y2P | GAVH 16- Y2P | GAVH 22- Y3P | GAVH 26- Y3P | GAVH 31- Y3P | GAVH 41- Y3K | ||
| Condition:35℃/24℃ Outlet Water Temperature:7℃ | Rated Cooling Capacity | kW | 5.1 | 7.8 | 10.0 | 13.0 | 15.8 | 21.8 | 26.0 | 30.4 | 40.5 |
| Power | kW | 1.7 | 2.7 | 3.4 | 4.2 | 5.3 | 7.0 | 9.0 | 10.0 | 14.0 | |
| COP | / | 3.0 | 2.9 | 2.9 | 3.1 | 3.0 | 3.1 | 2.9 | 3.0 | 2.9 | |
| Condition:7℃/6℃ Outlet Water Temperature:45℃ | Rated Cooling Capacity | kW | 6.3 | 9.1 | 12.0 | 15.0 | 18.0 | 27.7 | 33.0 | 34.0 | 46.0 |
| Power | kW | 1.8 | 2.6 | 2.8 | 4.3 | 5.6 | 8.0 | 9.7 | 10.0 | 13.4 | |
| COP | / | 3.6 | 3.5 | 4.3 | 3.5 | 3.2 | 3.5 | 3.4 | 3.4 | 3.4 | |
| Condition:-12C/-14°℃ Outlet Water Temperature:41℃ | Rated Cooling Capacity | kW | 3.9 | 5.6 | 7.3 | 9.6 | 11.2 | 21.0 | 23.0 | 27.0 | 30.0 |
| Power | kW | 1.4 | 2.0 | 2.3 | 3.6 | 4.4 | 7.8 | 8.6 | 9.7 | 11.5 | |
| COP | / | 2.8 | 2.8 | 3.2 | 2.7 | 2.5 | 2.7 | 2.7 | 2.8 | 2.6 | |
| Power Supply | 220V~50Hz | 380V 3N~50Hz | |||||||||
| Maximum Operating Power | kW | 2.2 | 3.5 | 4.0 | 6.0 | 6.6 | 9.6 | 11.0 | 12.0 | 22.5 | |
| Maximum Operating Current | A | 10.0 | 16.0 | 18.2 | 27.2 | 30.0 | 15.4 | 17.6 | 19.2 | 36.0 | |
| R410A Refrigerant | Charge | kg | 1.2 | 1.8 | 2.3 | 3.7 | 3.7 | 5.5 | 6.8 | 7.2 | 7.2 |
| Water-side Heat Exchanger | Rated Water Flow | m³/h | 0.9 | 1.3 | 1.7 | 2.2 | 2.7 | 3.8 | 4.5 | 5.2 | 7.0 |
| Connection Size | / | G1″Internal Thread | G5/4″Internal Thread | DN40 Flange | |||||||
| Water-side Pressure Loss | kPa | 30 | 45 | 30 | 15 | ||||||
| Dimensions | W×D×H | mm | 842*375*600 | 1065*445*863 | 1100*490*1402 | 1100*400*1568 | 1120*413*1545 | 1300*900*2010 | |||
| Noise | dB(A) | ≤48 | ≤48 | ≤48 | ≤50 | ≤50 | ≤55 | ≤55 | ≤55 | ≤60 | |
| Weight | kg | 32 | 57 | 60 | 120 | 120 | 180 | 200 | 200 | 360 | |
| Note: The above performance parameters are based on simulated conditions for reference only. Actual parameters shall be subject to the product nameplate. Product appearance may be updated; the image is for reference only. | |||||||||||