Packaged Air Handling Unit
- Wide & Scalable Airflow
Each packaged air handling unit covers about 2,000–20,000 m³/h. If you need more air, we can combine several units for you and size the airflow based on your workshop or building. - Quick to Install
With built-in heating and cooling, you don’t need a separate chiller or complex piping. This makes the unit easier to place on site and helps your team finish installation and commissioning faster. - Supply Air Set for Your Needs
The unit can keep supplying air close to your target temperature. You tell us your required conditions, and we adjust the design so the room stays stable and comfortable for your people and your process.
GEAREA Packaged Air Handling Unit Highlights
GEAREA packaged air handling unit pursue ultra-quiet, precisely controlled, ultra-dry, and energy-saving operation with patented technologies.

With condensation heat recovery, an inverter compressor, and EC fans working together, the system delivers around 40–50% energy savings.

GEAREA condensing heat redistribution system regulating heat from the built-in refrigeration cycle allows for precise humidity and temperature control.

GEAREA advanced humidity control technology can supply air with variable moisture content from 8 g/kg in summer to 12 g/kg in winter.

Distributed damping vibration and noise control technology brings the operation noise down to 65 dB(A), allowing for quiet work space.
GEAREA Revolutionary Technology on Packaged Air Handling Unit
GEAREA packaged air handling units combine cooling and heating into a single unit, eliminating the need for separate chiller units and complex chilled water piping. By using refrigerant directly for cooling, our packaged air handling units are quicker to install, easier to place on-site, and reduce the number of components you need to procure, coordinate, and maintain. For projects requiring reliable comfort or specific process conditions, these packaged air handling units provide a stable source of cooling and heat and uninterrupted heating, helping your plant or building operate smoothly while simplifying the entire HVAC system.

More About Packaged Air Handling Unit
- Data Sheet
| Model | GRDF-0.3 | GRDF-0.5 | GRDF-02 | GRDF-03 | GRDF-04 | GRDF-05 | GRDF-06 | GRDF-07 | GRDF-08 | GRDF-09 | GRDF-10 | GRDF-12 | GRDF-14 | GRDF-16 | GRDF-18 | GRDF-20 | ||
| Airflow | Rated | m³/h | 300 | 500 | 2000 | 3000 | 4000 | 5000 | 6000 | 7000 | 8000 | 9000 | 1000 | 12000 | 14000 | 16000 | 18000 | 20000 |
| Cooling & Dehumidification Operation | Rated Cooling Capacity | kW | 5.1 | 8.5 | 40.7 | 61.0 | 81.3 | 101.7 | 122.0 | 142.4 | 162.7 | 183.1 | 203.4 | 244.1 | 284.8 | 325.4 | 366.1 | 406.8 |
| Rated Dehumidification Capacity | kg/h | 4.5 | 7.5 | 32.8 | 49.2 | 65.5 | 82.0 | 98.4 | 114.8 | 131.2 | 147.6 | 164.0 | 196.8 | 229.6 | 262.4 | 295.2 | 328.0 | |
| Heating & Dehumidification Operation | Rated Heating Capacity | kW | 4.9 | 8.2 | 23.3 | 35.0 | 46.6 | 58.3 | 69.9 | 81.6 | 93.2 | 104.9 | 116.5 | 139.8 | 163.1 | 186.4 | 209.7 | 209.7 |
| Rated Humidification Capacity | kg/h | 3.1 | 5.2 | 16.6 | 24.9 | 33.3 | 41.6 | 49.9 | 58.2 | 66.6 | 74.9 | 83.2 | 99.8 | 116.5 | 133.1 | 149.8 | 233.0 | |
| Dimensions | Length | mm | 1000 | 1200 | 4500 | 4500 | 4500 | 4850 | 5000 | 5000 | 5000 | 5000 | 5200 | 5200 | 5400 | 5600 | 5600 | 5600 |
| Width | mm | 420 | 500 | 1100 | 1250 | 1400 | 1600 | 1800 | 2000 | 2000 | 2000 | 2000 | 2000 | 2250 | 2400 | 2400 | 2400 | |
| Height | mm | 935 | 1370 | 900 | 1000 | 1100 | 1100 | 1100 | 1200 | 1300 | 1400 | 1500 | 1700 | 1800 | 1900 | 1900 | 2000 | |
| Power Supply 380V/3N`/50Hz | 220V/50Hz | 380V/3N/50Hz | ||||||||||||||||
| Installed Power | kW | 2.4 | 4 | 21 | 31.2 | 40 | 50.9 | 54.4 | 70.6 | 83.3 | 92.1 | 103.6 | 121.6 | 134.6 | 151.1 | 177.6 | 184.6 | |
| External Static Pressure | Pa | 150 | 150 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | |
| Noise Level | dB(A) | 57 | 59 | 59 | 60 | 61 | 61 | 62 | 63 | 63 | 64 | 64 | 64 | 65 | 65 | 66 | 66 | |
| Humidification Section | Hot Water Flowrate | kg/h | 4 | 6.7 | 25.0 | 37.5 | 50 | 62.5 | 75.0 | 87.5 | 100 | 112.5 | 125 | 150 | 175 | 200 | 225 | 250 |
| Humidifier Make-Up Water Flowrate | DN | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Operating Weight | kg | 100 | 150 | 960 | 1050 | 1160 | 1280 | 1350 | 1480 | 1620 | 1780 | 1960 | 2120 | 2350 | 2580 | 2760 | 2950 | |